Asko Appliances AB
CIRCUIT DIAGRAM WM70.3
80 886 17 - 00
WIRES IN ALL MACHINES
INTERNAL CONNECTION
WIRES IN SOME MACHINES
RESISTANCES AT ROOM TEMPERATURE (CA. 20°C/68°F)
VALUES WITH +/-10% ARE REGARDED AS NORMAL COMPONENT
F: RADIO INTERFERENCE SUPPRESSION FILTER 680K Ohm
EL: HEATING ELEMENT 25 Ohm
AP: DRAIN PUMP 50 Hz 144 Ohm
AP: DRAIN PUMP 60 Hz 76 Ohm
LL: DOOR LOCK 122 Ohm
NTC: THERMISTOR 6.1 - 3.8 K Ohm
IV 1: INLET VALVE 1 3.7 K Ohm
IV 2: INLET VALVE 2 3.7 K Ohm
MO: MOTOR, 1-3 4,3±7% Ohm
1-2 4,3
±7% Ohm
2-3 4,3
±7% Ohm
*A FUSE CONNECTION USA & CANADA
CABLE POSITIONS
1: MOTOR COMMUNICATION
2: THERMISTOR
3: INLET VALVES
4: DOOR LOCK, DRAIN PUMP, PREASSURE SWITCH
TB: POWER
EL: HEATING ELEMENT, PREASSURE SWITCH
MO: MOTOR POWER