Asko H8 Spécifications Page 49

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 66
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 48
49
Defect in
Water
Level
Detection
E9
• Water supply greater than
the selected water level
• Continuous water supply
in high water level
• Water supply smaller than
the selected water level
• Reset level not detected
• Water level detection too
high or low
• Defect in pressure sensor
(damage in oscillation
condenser)
• Foreign substances in air
trip inlet
• Defect in PCB valve
• Foreign substance in air trip inlet
• Low frequency of pressure
sensor water level
• Defect in PCB
• Pressure sensor hose bent or
partially blocked
• Defect in pressure sensor
• Air leakage from pressure sensor
hose
• Defect in water level
detection circuit
• Defect in pressure sensor
• Defect in PCB
• Defect in water level
detection circuit
Vue de la page 48
1 2 ... 44 45 46 47 48 49 50 51 52 53 54 ... 65 66

Commentaires sur ces manuels

Pas de commentaire